Analyzers
Drivers for the analyzers in your laboratory.
BIOLIS reads results straight from your analyzers, over serial or network. Here are today's drivers, with their protocols and connection direction.
- models with drivers
- 37
- lab sections
- 9
- running at clients
- 6
- brands connected
- nearly 200
How it works
From analyzer to worklist, without guessing.
A short sample number from the analyzer is never turned into a lab number on its own. When in doubt, BIOLIS asks an analyst.
- 01
Analyzer sends
Results leave as HL7, ASTM, or serial text, over LAN or an RS-232 cable.
- 02
Listener receives
A BIOLIS listener on the server or a companion PC stores every raw message.
- 03
Results mapped
Analyzer test codes are matched exactly to BIOLIS codes, then rounded per test rule.
- 04
Into the worklist
Sample matches: result appears. No match: it waits for an analyst on Data Sync.

Bidirectional (host query)
ALL PLANSThe analyzer asks BIOLIS for the test list when a tube barcode is scanned. No order entry on the analyzer.
Histograms & scattergrams
ALL PLANSImages from hematology analyzers are stored and can be printed with the report.
QC results from analyzers
ENTERPRISEControl results from analyzers feed the QC module for Westgard evaluation.
Protocols
- HL7 v2.x · MLLP over TCP/IP
- ASTM E1381 / E1394 · LIS2-A2, serial or network
- RS-232 · through a companion PC next to the analyzer
- TCP/IP · directly over the lab LAN
- Shared folder · result files exported by the analyzer
Analyzer list
Drivers available today.
"Running at clients" means the driver is in use at a client laboratory. "Driver available" means the interface code exists; final testing happens on site during installation.
37 analyzers shown
| Brand & model | Section | Protocol | Link | Direction | Status |
|---|---|---|---|---|---|
| Mindray BC-720 / BC-760 / BC-780 | Hematology | HL7 v2.3.1 | TCP/IP | Bidirectional | Running at clients |
| Mindray BC-3600 | Hematology | HL7 v2.3.1 | RS-232 · TCP/IP | Bidirectional | Driver available |
| Mindray BC-6800 / BC-6900 (CAL) | Hematology | HL7 v2.3.1 | TCP/IP | Bidirectional | Driver available |
| Sysmex XN-350 / 450 / 550 | Hematology | ASTM E1394 | TCP/IP | Bidirectional | Driver available |
| Siemens ADVIA 560 | Hematology | HL7 v2.5 | RS-232 · TCP/IP | Bidirectional | Driver available |
| HUMAN HumaCount 5D | Hematology | HL7 | TCP/IP | Bidirectional | Driver available |
| Mindray BS-240 / 430 / 480 / 620 / 800 | Clinical chemistry | ASTM E1394 | TCP/IP | Bidirectional | Running at clients |
| Tokyo Boeki BiOLiS 30i | Clinical chemistry | HL7 v2.5 | TCP/IP | Bidirectional | Running at clients |
| Tokyo Boeki BiOLiS 24i Premium | Clinical chemistry | ASTM E1394 | RS-232 | Bidirectional | Driver available |
| Siemens Dimension EXL 200 | Clinical chemistry | Siemens DLC | RS-232 | Bidirectional | Driver available |
| HUMAN HumaStar 100 / 200 / 300SR | Clinical chemistry | ASTM | Folder LAN | Bidirectional | Driver available |
| HUMAN HumaCombilyzer | Clinical chemistry | ASTM LIS2-A2 | RS-232 · TCP/IP | One-way | Driver available |
| Wondfo Accre 8 | Immunology | HL7 v2.4 | TCP/IP | One-way | Running at clients |
| Mindray Immunoassay | Immunology | ASTM E1394 | TCP/IP | Bidirectional | Driver available |
| Insight U120 | Urinalysis | Teks serial | RS-232 | One-way | Running at clients |
| Insight U500 | Urinalysis | Teks serial | RS-232 | One-way | Driver available |
| ARKRAY PocketChem UA PU-4010 | Urinalysis | ASTM E1394 | RS-232 · LAN | One-way | Driver available |
| Sysmex UF-1500 | Urinalysis | ASTM E1394 | RS-232 · TCP/IP | One-way | Driver available |
| Dirui R-600S / AS-720 | Urinalysis | Teks serial | RS-232 | One-way | Driver available |
| Zybio U3600 | Urinalysis | HL7 v2.3.1 | TCP/IP | Bidirectional | Driver available |
| Erba LAURA | Urinalysis | ASTM E1394 | RS-232 · TCP/IP | One-way | Driver available |
| Diestro 103 AP / EX Auto Plus | Electrolytes & blood gas | Teks serial | RS-232 | One-way | Running at clients |
| SUNGO CBS-300 / 400 | Electrolytes & blood gas | Teks serial | RS-232 | One-way | Driver available |
| EXIAS e|1 | Electrolytes & blood gas | LIS2-A2 | TCP/IP | One-way | Driver available |
| Sensacore ST-200SC | Electrolytes & blood gas | Teks serial | UART | One-way | Driver available |
| AFT / Cornley AFT-500 · PR-703 / 705 | Electrolytes & blood gas | Teks serial | RS-232 | One-way | Driver available |
| Cornley AFTC | Electrolytes & blood gas | HL7 v2.3.1 | RS-232 | One-way | Driver available |
| Stago STart Max | Coagulation | ASTM LIS2-A2 | RS-232 | One-way | Driver available |
| Wondfo FS-113 | Coagulation | HL7 v2.4 | TCP/IP | One-way | Driver available |
| Tosoh HLC-723GX | HbA1c | Format host | RS-232 | One-way | Driver available |
| Lifotronic GH-900 Plus | HbA1c | ASTM E1394 | RS-232 · TCP/IP | Bidirectional | Driver available |
| Mindray TDR-300B Plus | Microbiology | ASTM · HL7 | RS-232 | Bidirectional | Driver available |
| Siemens epoc | POCT | HL7 v2.6 | TCP/IP · folder | One-way | Driver available |
| Biosensor F200 | POCT | HL7 v2.6 | TCP/IP | One-way | Driver available |
| BIOTIME FLI-100 | POCT | HL7 v2.3.1 | TCP/IP | One-way | Driver available |
| FiaFlex FIA-100 | POCT | HL7 v2.3.1 | RS-232 · TCP/IP | One-way | Driver available |
| Boditech i-CHROMA 2 | POCT | Boditech LIS | RS-232 · TCP/IP | One-way | Driver available |
Analyzer brand and model names belong to their respective owners.
Your analyzer isn't listed?
Mention the brand and model when you request a demo. Our team reviews its communication protocol documents and tells you what's needed.